(Ref: 113) Collapsed and milled out casing

(Ref: 113) Collapsed and milled out casing

In this video the client deployed our Capture Live HD camera system to inspect an unknown restriction after completing their operations. The video indicates that the client has milled through the cement inside of the casing, through the casing, through the cement on the outside of the casing, and then into open formation. Both the side and down view cameras positively identify the edges of the missing vertical section of the casing wall with cement visible on the inside and outside of where the casing was previously located. At the top right of the screen surrounding our logo; the open formation is visible. From the video, the customer was able to accurately evaluate the condition of the wellbore to properly plan their path moving forward. As an interesting side note, the clip shows shards of fine metal particulates, that are magnetized to the edge of the milled casing, waving back and forth with the pump rate. Find out more www.dhvi.net